120 inches · actual 3.5-inch trim

10-ft Board and Batten Wall: 1x4, 24-inch Gap Target

This layout uses 4 vertical battens with 21.2 in (≈ 21 3/16″) clear gaps. Both outside margins match the gaps between battens; no board sits flush at either end.

Adjust this layout in the calculator
Vertical battens
4
Actual clear gap
21.2 in (≈ 21 3/16″)
Center-to-center spacing
24.7 in (≈ 24 11/16″)
Vertical material · no waste
20 ft
4 battens, 21.2 inch clear gaps120 in wall widthFront elevation • horizontal scale only

Horizontal scale only. Height assumed: 60 inches per vertical piece. Fractions approximate the nearest 1/16 inch.

Batten marks from the left boundary (inches; fractions rounded to 1/16)
BattenLeft edgeCenter
121.2 in (≈ 21 3/16″)22.95 in (≈ 22 15/16″)
245.9 in (≈ 45 7/8″)47.65 in (≈ 47 5/8″)
370.6 in (≈ 70 5/8″)72.35 in (≈ 72 3/8″)
495.3 in (≈ 95 5/16″)97.05 in (≈ 97 1/16″)

How this 10-foot layout works

The measured span is 120 inches, with an actual face width of 3.5 inches for each nominal 1x4 strip. The 24-inch target is a maximum edge-to-edge gap, not a center mark. This arrangement has 5 equal spaces and uses 14 inches of the span for the boards themselves.

Actual clear gap: (120 − 4 × 3.5) ÷ 5 = 21.2 in
Pitch: 21.2 + 3.5 = 24.7 in

The wall midpoint at 60 in (≈ 60″) falls in the center of a clear opening. Use that observation when checking how the pattern lines up behind furniture or beneath a centered picture. The first left edge is 21.2 in (≈ 21 3/16″); the last left edge is 95.3 in (≈ 95 5/16″). The last board's right edge lands at 98.8 in (≈ 98 13/16″), leaving 21.2 in (≈ 21 3/16″) of clear wall at the right.

Two useful alternatives before you cut

Adding flush end boards changes this same wall to 6 battens and 19.8 in (≈ 19 13/16″) clear gaps. The vertical material estimate then becomes 30 feet at the same cut height. This is a different boundary rule; do not mix the location table above with that alternative.

Keeping the current end rule but increasing the maximum target to 28 inches produces 3 battens and 27.375 in (≈ 27 3/8″) gaps. That removes 1 vertical pieces, creating larger openings. Compare these dimensions with tape strips on the wall rather than judging the small diagram alone.

A cut-length and marking check

At a 60-inch cut height, the 4 pieces total 240 inches, or 20 linear feet. That figure includes only these vertical pieces. It excludes rails, backing, saw kerf, waste, and any existing boards outside the span. Check whether the stock lengths you can buy yield the required complete pieces. Short offcuts cannot be added together to make one continuous batten.

All positions are measured from the left boundary. Use the decimal marks if your measuring method supports them; the fractions are independent rounded tape marks. Do not repeatedly add the rounded 21 3/16-inch spacer value. Check outlet cover plates, window trim, and the width at more than one height before committing to this pattern. If the actual span differs from 120 inches, open this example in the main calculator and replace the width.